Factory and heavy industry · 9 models

Industrial Kerosene Heater 9 Models, 30–190 kW

An industrial kerosene heater is specified by the size of the space and by whether people are working in it. 9 of our 28 diesel and kerosene models list an industrial application — factory floors, production workshops, aircraft hangars, shipyards, steel fabrication shops and the largest project halls. Output runs 30 kW to 190 kW, or 102,364 to 648,307 BTU/h.

The 7 direct-fired models in this group move the most air for the least money and are the ones used in high, well-ventilated buildings: the FS190-20C at 190 kW is the most powerful heater we build. The 2 indirect-fired models in the group exist for the opposite case — 3 of the 9 are specified where air quality, humidity or dust control is part of the job, because the flue gases never enter the heated air.

Build is common across the group rather than graded by price: 441-grade stainless steel combustion chambers rated to 1000°C, overheat cut-off, heat-dissipation protection, flameout protection, shutdown protection and an error indicator light on every model, and an electrical load that covers only the fan motor, ignition and fuel pump. Every model on this page is built for diesel or kerosene only — no model here is approved for petrol or bio-oil.

Request a Quote See All 9 Models

115kW Diesel Heater for Heavy Industry Buildings FS115-20C
Key Figures

Industrial Diesel and Kerosene Heaters at a Glance

Every model here lists a factory, industrial hall, shipyard or fabrication shop as its recommended application. BTU/h is converted from the published kW rating at 1 kW = 3,412.14 BTU/h.

9models specified for industrial use
30–190 kWheat output across these models
102,364–648,307BTU/h equivalent, low to high
7 / 2direct fired versus indirect fired
Specification Table

Industrial Kerosene Heaters — Full Specification

Heat output as published on each model’s own specification sheet. The BTU/h column is the kilowatt figure converted at 1 kW = 3,412.14 BTU/h — it is a conversion, not a second rating.

Industrial diesel and kerosene heater range — specification
ModelHeat outputEquivalentFiringRecommended use
FS30-19A30 kW102,364 BTU/hDirect firedMedium workshops, warehouses, factory aisles
FS50-19A50 kW170,607 BTU/hDirect firedLarge workshops, factory floors, hangars
FS60-19A60 kW204,728 BTU/hDirect firedLarge industrial halls, production workshops
FS80-20C80 kW272,971 BTU/hDirect firedLarge warehouses, aircraft and equipment hangars
FS100-20C100 kW341,214 BTU/hDirect firedFactory units, large construction sites, temporary site offices
FS115-20C115 kW392,396 BTU/hDirect firedHeavy industry, shipyards, steel and fabrication shops
FS190-20C190 kW648,307 BTU/hDirect firedLargest industrial halls, major project and event heating
FS60-19BI60 kW204,728 BTU/hIndirect firedLarge clean-air industrial spaces, workshops
FS80-20CI80 kW272,971 BTU/hIndirect firedLarge warehouses with humidity control, industrial drying
Output Steps

Output Steps on This Page

Output is stepped. This table groups the industrial models by output step so you can see which bodies share a rating.

Industrial diesel and kerosene heater range — output steps
Output stepEquivalentModelsModel codes
30 kW102,364 BTU/h1FS30-19A
50 kW170,607 BTU/h1FS50-19A
60 kW204,728 BTU/h2FS60-19A, FS60-19BI
80 kW272,971 BTU/h2FS80-20C, FS80-20CI
100 kW341,214 BTU/h1FS100-20C
115 kW392,396 BTU/h1FS115-20C
190 kW648,307 BTU/h1FS190-20C
Where They Sell

What an Industrial Kerosene Heater Is Specified For

Industrial buyers are matching output to a volume, and firing type to what else is in the air.

Factory floors and production workshops

The largest group in this range. 9 of our 28 models list an industrial application, from 30 kW up to 190 kW.

Shipyards, steel and fabrication shops

High, draughty buildings that are heated by air volume rather than by surface temperature. The 7 direct-fired models here are built for exactly that.

Hangars, halls and clean-air process areas

Where humidity, coating or dust control matters, the 2 indirect-fired models in this group deliver heat without putting combustion product into the room.

FAQ

Industrial Kerosene Heaters — Common Questions

How many kW do I need for an industrial space?

This range runs 30 kW to 190 kW. Volume and ventilation decide it: a sealed workshop needs far less than an open-fronted bay of the same floor area. Send us the dimensions and we will size it.

Direct or indirect fired for a factory?

7 of the 9 models here are direct fired and 2 are indirect. If people work in the space all day, or if there is dust, coating or food in the air, specify indirect. If the building is high and ventilated, direct is cheaper per kW delivered.

What is the largest industrial heater you make?

The FS190-20C at 190 kW, or 648,307 BTU/h. The smallest model on this page is the FS30-19A at 30 kW.

Can these run on kerosene as well as diesel?

Yes. All 9 models are built for diesel or kerosene. Petrol and bio-oil are excluded on every specification sheet in this category.

Do the indirect-fired models need a flue?

Yes — all 2 of them require the combustion gases to be ducted outside. The 7 direct-fired models do not; they are used with ventilation.

Are these suitable for occupied production areas?

The 2 indirect-fired models are: the flame never touches the delivered air. Direct-fired units are for ventilated buildings. See the full diesel and kerosene range to compare.

Need Industrial Kerosene Heater Pricing?

Send the model, the specification you want, your market and the target quantity — we reply within 24 hours with FOB pricing, lead time and a loading plan.

Send Inquiry